Designed for Small-to-Medium Hydrogen Scenarios
The HRP1000A air-cooled IGBT hydrogen power supply features a modular architecture with a power range of 
100kW–5MW, suitable for distributed hydrogen stations, industrial park green hydrogen supply, and R&D pilot projects, offering versatile adaptability.
Product model :
HRP1000AProduct parameters :
1000 m³/hHigh Power Density: Advanced IGBT devices paired with an intelligent air-cooled thermal system achieve 1.0kW/L power density, reducing size by 35% and saving space and installation costs.
Ultimate Efficiency: Peak efficiency ≥97.5% , with overall energy consumption reduced by 18%, saving over 400,000 kWh annually.
IP54 Protection: Dustproof and waterproof design, resistant to humidity, salt spray, and dust, ideal for coastal, desert, and industrial environments.
Wide Temperature Range: Operational from -25°C to +50°C (auto-derating above 45°C), altitude ≤4,000 meters, validated by 72-hour rigorous endurance testing.
Millisecond Dynamic Response: Full-power adjustment time ≤100ms, perfectly adapting to renewable energy fluctuations and increasing curtailed energy utilization by 25%.
Digital Monitoring: 7-inch industrial touchscreen displays real-time voltage, current, efficiency, and 20+ parameters. Supports Modbus for seamless integration with Energy Management Systems (EMS).
⇒ Product Parameter
Product Parameter
| 
 product  | 
 HRP1000A  | 
||
| 
 hydrogen yield  | 
 500  | 
||
| 
 AC input parameters  | 
 AC voltage range  | 
 600V ac  | 
|
| 
 Permissible grid  | 
 ±10%  | 
||
| 
 Rated grid frequency  | 
 50/60Hz  | 
||
| 
 Permissible grid  | 
 ±10%  | 
||
| 
 Power Factor  | 
 ≥0.99  | 
||
| 
 Power factor range  | 
 0.9 leading~0.9 lagging  | 
||
| 
 Current harmonic  | 
 ≤3%  | 
||
| 
 Access method  | 
 3P3L + PE  | 
||
| 
 DC output parameters  | 
 Output Power  | 
 5000kW  | 
|
| 
 Maximum Power  | 
 110% maximum output  | 
||
| 
 Electrolyser type  | 
 High Voltage  | 
 Low Voltage  | 
|
| 
 Maximum DC current (A)  | 
 9600  | 
 19200  | 
|
| 
 Maximum DC voltage (V)  | 
 820  | 
 410  | 
|
| 
 Current range  | 
 0~Maximum output current  | 
||
| 
 Voltage range  | 
 0~Maximum output voltage  | 
||
| 
 Current ripple  | 
 ≤1%-Ipp  | 
||
| 
 Current accuracy  | 
 ≤0.5%×maximum current  | 
||
| 
 Dynamic response time  | 
 ≤100ms, slope can be set  | 
||
| 
 Control method  | 
 Constant current Constant voltage Constant power  | 
||
| 
 Highest efficiency  | 
 97.50%  | 
 97.00%  | 
|
| 
 General parameters  | 
 Dimensions  | 
 3550×2400×2205  | 
|
| 
 Protection level  | 
 IP20 , IP54  | 
||
| 
 Temperature range  | 
 -35~60℃  | 
||
| 
 Humidity range  | 
 0~95% No condensation  | 
||
| 
 Fault recording and broadcasting diagnosis  | 
 Including  | 
||
| 
 Process interlocking  | 
 Including  | 
||
| 
 Communication interface  | 
 RS485, Modbus RTU, Modbus TCP  | 
||
| 
 Human-computer interaction interface  | 
 10-inch touch screen interaction  | 
||
| 
 Inport and outport  | 
 Up in /Down out  | 
||
Our hours
Mon 11/21 - Wed 11/23: 9 AM - 8 PM
Thu 11/24: closed - Happy Thanksgiving!
Fri 11/25: 8 AM - 10 PM
Sat 11/26 - Sun 11/27: 10 AM - 9 PM
(all hours are Eastern Time)