1000 SCM Large Capacity Electrolyser power supply for PEM
Designed for PEM type electrolysers, better adapted to high current densities.
External step-down transformer for frequency isolation and higher efficiency.
DC Harmonic ≤ 3%,power factor ≥ 0.99.
DC voltage ripple ≤ 1%
Intelligent liquid cooling will effectively improve the life of devices and the whole equipment
IP54 protection for better adaptation to complex environments
Unique P/I curve setting function
Full-power regulation response time ≤ 100ms
Product model :
HRP1000PProduct parameters :
1000Precision Compatibility: Custom-designed for the low-voltage, high-current characteristics of PEM electrolyzers, supporting millisecond-level dynamic power adjustment to seamlessly adapt to fluctuating renewable energy inputs.
IP54 Protection: Fully sealed dustproof and waterproof design, resistant to high humidity, salt spray, and dust, ideal for coastal, desert, and industrial environments.
High Power Density: Advanced IGBT devices paired with a liquid-cooled heat dissipation system achieve 1.5kW/L power density, reducing size by 50% compared to traditional solutions.
Ultimate Efficiency: Maximum efficiency ≥97.5%, with overall energy consumption reduced by 20%.
Clean Power Output: Power factor ≥0.99, current harmonic distortion (THD) ≤0.5%, compliant with IEEE 519 standards—no additional filtering required.
Smart Energy Feedback: Supports reactive power compensation and energy feedback functions, alleviating grid load pressure.
P/I Adaptive Output: Proprietary power-current regulation algorithm dynamically optimizes electrolyzer operation, limiting hydrogen output fluctuations to <2%.
Full-Chain Monitoring: Built-in high-precision sensors and diagnostic system enable remote emergency shutdown and data traceability.
⇒ Product Parameter
| 
 product  | 
 HRP1000P  | 
||
| 
 hydrogen yield (m³/h)  | 
 1000  | 
||
| 
 AC input parameters  | 
 AC voltage range  | 
 400~600V ac  | 
|
| 
 Permissible grid voltage range  | 
 ±10%  | 
||
| 
 Rated grid frequency  | 
 50/60Hz  | 
||
| 
 Permissible grid frequency range  | 
 ±10%  | 
||
| 
 Power Factor  | 
 ≥0.99  | 
||
| 
 Power factor range  | 
 0.9 leading~0.9 lagging  | 
||
| 
 Current harmonic distortion  | 
 ≤3%  | 
||
| 
 Access method  | 
 3P3L + PE  | 
||
| 
 DC output parameters  | 
 Output Power  | 
 5000kW  | 
|
| 
 Maximum Power  | 
 110% maximum output  | 
||
| 
 Maximum DC current (A)  | 
 12000  | 
||
| 
 Maximum DC voltage (V)  | 
 900  | 
||
| 
 Current range  | 
 0~Maximum output current  | 
||
| 
 Voltage range  | 
 0~Maximum output voltage  | 
||
| 
 Current ripple  | 
 ≤1%-Ipp  | 
||
| 
 Current accuracy  | 
 ≤0.5%×maximum current  | 
||
| 
 Dynamic response  | 
 ≤100ms, slope can be set  | 
||
| 
 Control method  | 
 Constant current control  | 
||
| 
 General  | 
 Highest efficiency  | 
 97.50%  | 
|
| 
 Dimensions (W×D×H mm)  | 
 2720×1865×2305  | 
||
| 
 Protection level  | 
 IP54  | 
||
| 
 Temperature range  | 
 -35~60℃  | 
||
| 
 Humidity range  | 
 0~95% No condensation  | 
||
| 
 Fault recording and broadcasting diagnosis  | 
 Including  | 
||
| 
 Process interlocking  | 
 Including  | 
||
| 
 Communication interface  | 
 RS485, Modbus RTU, Modbus TCP  | 
||
| 
 Human-computer interaction interface  | 
 10-inch touch screen interaction  | 
||
| 
 Inport and outport  | 
 Up in /Down out  | 
||