2000 SCM Liquid-cooled IGBT electrolyser power supply
HRP2000L is a high-efficiency liquid-cooled hydrogen power supply designed for large-scale hydrogen production scenarios.
Utilizing advanced IGBT technology and an intelligent liquid-cooling system, it covers a power range of 500kW–2MW, ideal for green hydrogen bases, off-grid microgrids, and industrial byproduct hydrogen projects.
With high-frequency isolation technology and modular design, it achieves 98% peak efficiency, millisecond-level dynamic response, and stable operation from -35°C to +60°C, helping customers reduce hydrogen production costs by 30% and improve energy utilization by 25%.
Product model :
HRP2000LProduct parameters :
2000 m³/h
Integrated intelligent liquid-cooling system delivers 1.8kW/L power density, reducing size by 45% and improving heat dissipation efficiency by 50%.
Maintains ≥97.5% efficiency under full load at 45°C ambient temperature, with a 30% longer lifespan.
IGBT-based high-frequency soft-switching isolated DC/DC circuit achieves 3000VAC/1min electrical isolation, eliminating external industrial-frequency transformers.
IP54-rated protection withstands salt spray, dust, and high humidity, validated by 1,000-hour salt spray corrosion testing.
Supports constant current/voltage/power modes with ≤80ms full-power adjustment, adapting to renewable energy fluctuations.
Modular design allows single-unit 500kW output, expandable to 2MW (4 modules in parallel) without downtime.
⇒ Product Parameter
| 
 product  | 
 HRP2000L  | 
||
| 
 hydrogen yield (m³/h)  | 
 2000  | 
||
| 
 AC input parameters  | 
 AC voltage range  | 
 500/600V ac  | 
|
| 
 Permissible grid  | 
 ±10%  | 
||
| 
 voltage range  | 
|||
| 
 Rated grid frequency  | 
 50/60Hz  | 
||
| 
 Permissible grid  | 
 ±10%  | 
||
| 
 frequency range  | 
|||
| 
 Power Factor  | 
 ≥0.99  | 
||
| 
 Power factor range  | 
 0.9 leading~0.9 lagging  | 
||
| 
 Current harmonic  | 
 ≤3%  | 
||
| 
 distortion  | 
|||
| 
 Access method  | 
 3P3L + PE  | 
||
| 
 DC output parameters  | 
 Output Power  | 
 10000kW  | 
|
| 
 Maximum Power  | 
 110% maximum output  | 
||
| 
 Electrolyser type  | 
 High Voltage  | 
 Low Voltage  | 
|
| 
 Low Current  | 
 High Current  | 
||
| 
 Maximum DC current (A)  | 
 17600  | 
 26400  | 
|
| 
 Maximum DC voltage (V)  | 
 820  | 
 540  | 
|
| 
 Current range  | 
 0~Maximum output current  | 
||
| 
 Voltage range  | 
 0~Maximum output voltage  | 
||
| 
 Current ripple  | 
 ≤1%-Ipp  | 
||
| 
 Current accuracy  | 
 ≤0.5%×maximum current  | 
||
| 
 Dynamic response  | 
 ≤100ms, slope can be set  | 
||
| 
 Control method  | 
 Constant current control  | 
||
| 
 General  | 
 Highest efficiency  | 
 98%  | 
 97.50%  | 
| 
 Dimensions  | 
 2720×1865×2305  | 
||
| 
 (W×D×H mm)  | 
|||
| 
 Protection level  | 
 IP54  | 
||
| 
 Temperature range  | 
 -35~60℃  | 
||
| 
 Humidity range  | 
 0~95% No condensation  | 
||
| 
 Fault recording and  | 
 Including  | 
||
| 
 broadcasting diagnosis  | 
|||
| 
 Process interlocking  | 
 Including  | 
||
| 
 Communication interface  | 
 RS485, Modbus RTU, Modbus TCP  | 
||
| 
 Human-computer  | 
 10-inch touch screen interaction  | 
||
| 
 interaction interface  | 
|||
| 
 Inport and outport  | 
 Up in /Down out  | 
||